3.2 Performance Evaluation of the Optimized MARK-U3 System
Field evaluation of the optimized MARK-U3 system showed that the redesign yielded substantial improvements in all major operational categories.
Table 2 compares the key performance specifications between the baseline and the optimized system to quantify the degree of optimization.
Fig. 3 provides an overview of the improved MARK-U3 system, including its structural and hydraulic configuration. The calculation for the MDA is expressed as
Eq. (1), where the efficiency–volume (
ɛ–V) parameter is identified as a critical factor influencing MDA in gamma-ray spectrometry. To evaluate the variation in the
ɛ–V parameter resulting from an increase in sampling volume, the net count rates were assessed for 2 L and 3 L sample volumes from the Monte Carlo simulations. This was achieved by assuming a uniform distribution of photons within the container for each volume. Ten photon energies were simulated, ranging from 100 to 3,000 keV, with the results shown in
Fig. 4. Consequently, the
ɛ–V parameter for the 3 L volume revealed an approximately 30% increase across the entire energy range compared to the 2 L baseline. Accordingly, a critical enhancement in radiological detection sensitivity is anticipated. Although the baseline MARK-U3 system exhibited an MDA of approximately 1.13 Bq·L
−1 for a one-hour measurement (
Joung et al. 2023), the optimized system is expected to improve this detection limit to approximately 0.87 Bq·L
−1, representing a reduction of approximately 30%.
where, NB denotes the background counts, γEP represents the probability of gamma-ray emission, and t denotes the counting time.
Although the sampling container volume was expanded from 2 L to 3 L, the background count rate remained comparable to the baseline configuration. This stability was attributed primarily to the self-shielding effect of the seawater sample itself. Moreover, the intrinsic contribution of the seawater sample to the background count rate is negligible. Unlike terrestrial soil samples, natural seawater typically exhibits extremely low specific activity. Thus, increasing the sample volume does not result in a proportional increase in the background continuum relative to the detector efficiency. The distinct environmental advantage of the floating geometry must be noted. Operating on the sea surface isolates the system from terrestrial radionuclides (e.g., 40K, uranium, and thorium series found in soil), resulting in an inherently lower background environment than land-based measurements. Consequently, the combination of the sample’s self-shielding properties of a sample and the unique low-background marine environment ensures that the background rate remains stable even with the enlarged 3 L sampling container. Therefore, with the signal collected from the increased sample volume and the noise level held constant, the MDA is theoretically reduced by approximately 30% compared to the previous system.
Furthermore, the structural optimization played a pivotal role in minimizing the measurement uncertainty caused by environmental conditions. Unlike the previous version, which suffered from tilting under wave-induced motion, the optimized system, which was reinforced with ballast weights and buoyancy modules, maintained a stable vertical orientation. This structural stability ensures a constant measurement geometry between the detector and the sample, eliminating the geometry-induced systematic errors that often compromise the accuracy of in situ gamma-ray spectrometry. The sampling precision also showed marked improvement. During repeated trials under variable wave heights, the diaphragm pump maintained a stable flow rate without the pulsation or backflow issues frequently encountered with peristaltic systems. The integration of an overflow-based verification method provided highly consistent confirmation of volume completion, ensuring that the system achieved the intended 3 L sample volume regardless of buoy motion. This reliability was further reinforced by redundant hydraulic pathways, which minimized the risk of operational interruptions from particulate matter. Depth-controlled sampling represented another major enhancement. The cable-winch mechanism successfully positioned the sampling inlet at predefined depths with high precision, while the weighted pipe assembly minimized horizontal displacement. When coupled with CTD data, this depth-resolved sampling enables a more refined interpretation of radiological measurements by correlating radionuclide concentrations with hydrological stratification.
The lower section of the system comprises the ballast weight and its supporting structural frame, leaving substantial unused internal space that could be better utilized. Based on the seawater sampling automation requirements identified earlier, this space can be effectively allocated for installing the sampling pipeline, the cable-winch assembly, and a dedicated reservoir for cleaning water. In the revised design, the cable winch and ballast weight are positioned in the lower compartment, and the surrounding area will be used to accommodate an uncontaminated cleaning water storage tank for rinsing the sampling container. In addition, the provisions for pump redundancy are considered essential to ensure stable operation in the event of pump malfunction. The automated cleaning module will show a high level of effectiveness. After each cleaning cycle, radiological measurements from blank samples showed almost no residual activity, confirming that cross-contamination between sampling cycles had been successfully eliminated. This capability is particularly important for long-term deployment in areas where radiological conditions may change rapidly or where sequential measurements must remain independent.
Finally, the hybrid solar–battery power system can support uninterrupted operation over several days. Even during periods of reduced solar irradiance, essential system functions, including gamma-ray detection and remote communication, remained active. The LTE-based communication system maintained stable connectivity with the onshore control center, enabling near real-time monitoring and remote intervention throughout the test period. The LTE module transmits, in real time, sampling data, gamma-ray spectra, depth information, and diagnostic status to an onshore control center. Operators could initiate the sampling cycles, adjust depth settings, or trigger cleaning operations remotely.
3.3 Mobile Robot-Based Monitoring Concepts
The monitoring coverage was expanded by designing the MARK-U3 system for integration with a mobile water-quality robot.
Figs. 5 and
6 show the conceptual layout and a 3D model of the mobile robot-integrated MARK-U3 platform. The robot featured a 3×3×1.4 m floating frame equipped with propulsion motors, solar power units, LiDAR, IMU sensors, and a dedicated control module. MARK-U3 functioned as a modular payload, enabling automated sampling at multiple locations without redeployment. The integration of the MARK-U3 system with the mobile water-quality robot significantly expanded the spatial capabilities of marine radiological monitoring. In contrast to previous buoy systems (e.g.,
Song et al. 2023) that focused on stationary monitoring, the optimized MARK-U3 is expected to show a comparable or superior MDA (0.87 Bq·L
−1 based on these simulation results) while uniquely providing automated cleaning and mobile-robot-based spatial coverage. During field deployment, the robot successfully transported the MARK-U3 unit between multiple sampling stations separated by several hundred meters. At each location, the system performed sampling and analysis autonomously without requiring manual setup or recalibration. The combined platform maintained structural and operational stability while in transit. The reinforced flotation structure of the buoy effectively dampened lateral motion during movement, and sampling geometry remained consistent even after the robot changed heading or speed. This stability ensured that the sampling inlet returned to its correct operating configuration at each designated stop.
The measurements taken from different stations revealed noticeable spatial variability in environmental parameters and radiological signals. Such variability underscores the value of a mobile monitoring platform because fixed-point buoys may fail to capture dynamic or localized changes in marine radiological conditions. The field results showed that mobile deployment enables rapid identification of environmental anomalies and allows for adaptive sampling strategies during emergency-response operations. Overall, the integrated MARK-U3–robot system showed the ability to sustain continuous operation during extended field trials, collecting reliable radiological data at multiple locations, and highlighting its potential as a flexible tool for comprehensive marine environmental assessments.