J. Ocean Eng. Technol. Search

CLOSE


J. Ocean Eng. Technol. > Volume 40(3); 2026 > Article
Ji, Ji, Joung, Kim, and Chung: Optimization of a Floating Marine Radiological Monitoring System with Integrated Seawater Sampling and In Situ Gamma-Ray Spectrometry

Abstract

Marine radiological monitoring has long relied on manual seawater sampling, limiting the timeliness of environmental surveillance. This paper reports the optimization of the MARK-U3 (Monitoring of ambient radiation of KAERI-Underwater #3) buoy-type system, designed to enable fully automated seawater sampling, in situ gamma-ray spectrometry, and autonomous offshore operation. The technical requirements for improved sensitivity and stability were derived through system analysis, leading to a redesign featuring a 3 L sampling container, diaphragm pump-based overflow quantification, and a cable-winch depth-control mechanism. Field evaluations showed that increasing the sampling volume to 3 L, while maintaining the background count rate through the self-shielding effect of the seawater sample, theoretically reduced the minimum detectable activity (MDA) by approximately 1.3. Crucially, the structural reinforcement with ballast weights ensured vertical stability, maintaining a constant measurement geometry compared to the detector even under wave-induced motion. In addition, the automated cleaning module successfully eliminated cross-contamination. These results showed that the optimized MARK-U3 system is well-suited for routine marine radiological surveillance and rapid emergency-response applications.

Nomenclature

MDA:
Minimum detectable activity (Bq·L−1)
CTD:
Conductivity, temperature, depth sensor
LTE:
Long-Term evolution (communication)
LiDAR:
Light detection and ranging
IMU:
Inertial measurement unit
MARK-U3:
Monitoring of ambient radiation of KAERI-Underwater #3
KAERI:
Korea Atomic Energy Research Institute

1. Introduction

Marine radiological monitoring around nuclear facilities plays a crucial role in ensuring environmental safety and supporting emergency-response readiness. On the other hand, conventional monitoring relies primarily on manual seawater sampling, transportation to laboratories, and subsequent gamma-ray spectrometry. These processes require significant time and human resources, introducing delays that limit the ability to capture rapidly evolving radiological conditions. In addition, manual sampling provides only a coarse temporal and spatial resolution, rendering it unsuitable for scenarios involving dynamic radionuclide dispersion. Automated and semi-automated monitoring technologies have emerged to address these limitations, including onboard sample pretreatment systems installed on research vessels. Although these systems reduce the analytical time, they cannot operate without human presence and do not provide persistent offshore surveillance. Therefore, a technological gap remains in the form of a fully autonomous marine monitoring platform capable of repeatedly acquiring seawater samples, analyzing them in situ, and maintaining long-duration offshore operation (Song et al., 2023; Tsabaris et al., 2018; Zhang et al., 2022).
The Korea Atomic Energy Research Institute (KAERI) developed the initial version of the MARK-U3 floating marine monitoring system to address this need. The system integrates seawater sampling with in situ gamma-ray spectrometry in a buoy-type configuration capable of extended deployment (Joung et al., 2023). Nevertheless, field testing revealed several limitations related to sampling accuracy, buoyancy stability, lack of automated cleaning, absence of depth-resolved sampling, and constrained power autonomy. This study focused on the systematic redesign and optimization of the MARK-U3 system. The goal was to improve the sampling performance, radiological sensitivity, structural robustness, and operational autonomy. The development includes revised technical requirements, hydraulic and mechanical redesign, structural enhancement, and integration with a mobile water-quality robot. The following sections describe the methods used in the system redesign and the results obtained through field deployment. This study optimized the MARK-U3 floating marine radiological monitoring system by addressing the key limitations identified during initial deployments. An improved configuration capable of accurate seawater sampling, in situ gamma-ray spectrometry, and stable long-term autonomous offshore operation was developed.

2. Materials and Methods

2.1 System Design Requirements and Conceptual Framework

The optimization process began with a comprehensive review of the performance limitations observed during the initial deployments of the MARK-U3 system, as shown in Fig. 1. One of the most significant limitations was the insufficient sampling volume, which restricted the MDA achievable during in situ gamma-ray spectrometry. A target sampling volume of 3 L was selected to address this limitation. This volume represented a balance between improved radiological sensitivity and feasibility within the buoy-type structure. The optimization process involved finding a critical balance between increasing the sampling volume for higher sensitivity and managing the increased mass of radiation shielding to maintain the buoyancy and stability of a buoy. Increasing the sampling volume required the addition of supplementary radiation shielding to maintain low background conditions inside the detection chamber. Although additional shielding increased the overall system mass, the displacement of the buoy increased proportionally, which ultimately helped improve the floating stability. This structural adaptation helped mitigate a second major issue observed during the initial field trials: the instability and tilting of the buoy under wave-induced motion.
Mechanical and hydraulic design requirements were also derived. Wave-induced motion introduced variability in the flow rate and filling characteristics of the original sampling system. Consistent sample acquisition of the system was ensured using a pump architecture capable of maintaining performance under fluctuating pressure conditions. After evaluating multiple pump types, the diaphragm pump was selected for its stability and compatibility with marine conditions. An overflow-based verification approach was adopted to ensure accurate volumetric measurement, eliminating the need for complex sensors and providing a simple, robust indicator of volume completion.

2.2 Development of Sampling, Cleaning, and Depth-Control Mechanisms

The seawater sampling subsystem was redesigned to ensure reliable operation during repeated sampling cycles at sea. The diaphragm pump formed the core of the hydraulic architecture, providing a stable flow rate and strong resistance to clogging or pressure fluctuations. The overflow outlet served as a confirmation mechanism to ensure that the 3 L sampling container reached full capacity before the sampling cycle terminated. The hydraulic system also incorporated redundant flow pathways to reduce the likelihood of operational failure caused by pump or valve malfunctions. A cable-winch mechanism was integrated into the lower structure of the buoy to enable depth-resolved sampling. This mechanism allowed the sampling inlet to descend to predetermined depths, enabling monitoring of the depth-dependent radionuclide distribution. Weighted piping minimized the lateral drift and ensured stable vertical alignment during submersion. The sampling assembly was also designed to accommodate a conductivity–temperature–depth (CTD) sensor, allowing simultaneous acquisition of hydrological parameters. An automated cleaning concept was incorporated into the system design to prevent cross-contamination between successive sampling cycles, thereby improving the operational efficiency. The cleaning module uses uncontaminated water stored in a 20–30 L reservoir located within the lower frame of the buoy. Following the gamma-ray analysis of a potentially contaminated sample, the sampling container will be flushed automatically as part of the standard post-analysis procedure. When the cleaning reservoir becomes depleted, the system transitions to a measurement-only mode in which the container is used solely to monitor the changes in the residual radioactivity within the vessel.

2.3 Technical Requirement Analysis for Improving the MARK-U3 System

Table 1 lists the requirement analysis for raw seawater sampling technologies to improve the performance of the baseline floating in situ water sampling and measurement system (MARK-U3). The technical requirements for improving the MARK-U3 system focus on enhancing sampling capacity, hydraulic performance, environmental adaptability, and autonomous operation. Increasing the sampling container volume to 3 L and adopting a diaphragm pump with overflow-based verification were identified as essential for achieving a lower MDA and ensuring volumetric accuracy under offshore conditions. Stable depth-resolved sampling requires a weighted pipe and cable-winch configuration, while an automated cleaning system with a dedicated freshwater reservoir is necessary to prevent cross-contamination between sampling cycles. Furthermore, a low-power architecture combined with a hybrid solar-battery–hybrid supply and LTE-based control was determined to be crucial for sustaining multi-day autonomous operation in harsh marine environments.

3. Results and Discussions

3.1 Structural Stability Enhancement

The previously developed floating in situ seawater sampling system (Fig. 1) exhibited several structural limitations, most notably insufficient buoyancy, which prevented it from maintaining an upright orientation during underwater deployment. This instability caused the system to tilt, making it difficult to accurately assess the volume of water collected inside the sampling container. As a result, the actual sampling volume often deviated from the intended 2 L target, and inconsistencies in the geometric positioning of the sample within the container could introduce additional analytical errors during theoretical efficiency calibration. These issues were addressed by developing an optimized buoyancy design to enable stable, standalone operation of the MARK-U3 system. Buoyant foam tubes were installed on the upper frame to enhance the buoyancy of the existing MARK-U3 configuration, while a lower structural assembly combined with ballast weights was added to improve the vertical alignment and positional stability. Figure 2 illustrates the prototype design in which buoyancy-reinforcement components were integrated into the MARK-U3 platform. The total mass of the system was estimated to increase by approximately 10 kg compared to the baseline configuration due to the addition of ballast weights and structural reinforcements. Fig. 2 shows the optimized buoyancy-reinforcement configuration.

3.2 Performance Evaluation of the Optimized MARK-U3 System

Field evaluation of the optimized MARK-U3 system showed that the redesign yielded substantial improvements in all major operational categories. Table 2 compares the key performance specifications between the baseline and the optimized system to quantify the degree of optimization. Fig. 3 provides an overview of the improved MARK-U3 system, including its structural and hydraulic configuration. The calculation for the MDA is expressed as Eq. (1), where the efficiency–volume (ɛ–V) parameter is identified as a critical factor influencing MDA in gamma-ray spectrometry. To evaluate the variation in the ɛ–V parameter resulting from an increase in sampling volume, the net count rates were assessed for 2 L and 3 L sample volumes from the Monte Carlo simulations. This was achieved by assuming a uniform distribution of photons within the container for each volume. Ten photon energies were simulated, ranging from 100 to 3,000 keV, with the results shown in Fig. 4. Consequently, the ɛ–V parameter for the 3 L volume revealed an approximately 30% increase across the entire energy range compared to the 2 L baseline. Accordingly, a critical enhancement in radiological detection sensitivity is anticipated. Although the baseline MARK-U3 system exhibited an MDA of approximately 1.13 Bq·L−1 for a one-hour measurement (Joung et al. 2023), the optimized system is expected to improve this detection limit to approximately 0.87 Bq·L−1, representing a reduction of approximately 30%.
(1)
MDA=2.71+4.65NB(ɛ·V)×γEP×t
where, NB denotes the background counts, γEP represents the probability of gamma-ray emission, and t denotes the counting time.
Although the sampling container volume was expanded from 2 L to 3 L, the background count rate remained comparable to the baseline configuration. This stability was attributed primarily to the self-shielding effect of the seawater sample itself. Moreover, the intrinsic contribution of the seawater sample to the background count rate is negligible. Unlike terrestrial soil samples, natural seawater typically exhibits extremely low specific activity. Thus, increasing the sample volume does not result in a proportional increase in the background continuum relative to the detector efficiency. The distinct environmental advantage of the floating geometry must be noted. Operating on the sea surface isolates the system from terrestrial radionuclides (e.g., 40K, uranium, and thorium series found in soil), resulting in an inherently lower background environment than land-based measurements. Consequently, the combination of the sample’s self-shielding properties of a sample and the unique low-background marine environment ensures that the background rate remains stable even with the enlarged 3 L sampling container. Therefore, with the signal collected from the increased sample volume and the noise level held constant, the MDA is theoretically reduced by approximately 30% compared to the previous system.
Furthermore, the structural optimization played a pivotal role in minimizing the measurement uncertainty caused by environmental conditions. Unlike the previous version, which suffered from tilting under wave-induced motion, the optimized system, which was reinforced with ballast weights and buoyancy modules, maintained a stable vertical orientation. This structural stability ensures a constant measurement geometry between the detector and the sample, eliminating the geometry-induced systematic errors that often compromise the accuracy of in situ gamma-ray spectrometry. The sampling precision also showed marked improvement. During repeated trials under variable wave heights, the diaphragm pump maintained a stable flow rate without the pulsation or backflow issues frequently encountered with peristaltic systems. The integration of an overflow-based verification method provided highly consistent confirmation of volume completion, ensuring that the system achieved the intended 3 L sample volume regardless of buoy motion. This reliability was further reinforced by redundant hydraulic pathways, which minimized the risk of operational interruptions from particulate matter. Depth-controlled sampling represented another major enhancement. The cable-winch mechanism successfully positioned the sampling inlet at predefined depths with high precision, while the weighted pipe assembly minimized horizontal displacement. When coupled with CTD data, this depth-resolved sampling enables a more refined interpretation of radiological measurements by correlating radionuclide concentrations with hydrological stratification.
The lower section of the system comprises the ballast weight and its supporting structural frame, leaving substantial unused internal space that could be better utilized. Based on the seawater sampling automation requirements identified earlier, this space can be effectively allocated for installing the sampling pipeline, the cable-winch assembly, and a dedicated reservoir for cleaning water. In the revised design, the cable winch and ballast weight are positioned in the lower compartment, and the surrounding area will be used to accommodate an uncontaminated cleaning water storage tank for rinsing the sampling container. In addition, the provisions for pump redundancy are considered essential to ensure stable operation in the event of pump malfunction. The automated cleaning module will show a high level of effectiveness. After each cleaning cycle, radiological measurements from blank samples showed almost no residual activity, confirming that cross-contamination between sampling cycles had been successfully eliminated. This capability is particularly important for long-term deployment in areas where radiological conditions may change rapidly or where sequential measurements must remain independent.
Finally, the hybrid solar–battery power system can support uninterrupted operation over several days. Even during periods of reduced solar irradiance, essential system functions, including gamma-ray detection and remote communication, remained active. The LTE-based communication system maintained stable connectivity with the onshore control center, enabling near real-time monitoring and remote intervention throughout the test period. The LTE module transmits, in real time, sampling data, gamma-ray spectra, depth information, and diagnostic status to an onshore control center. Operators could initiate the sampling cycles, adjust depth settings, or trigger cleaning operations remotely.

3.3 Mobile Robot-Based Monitoring Concepts

The monitoring coverage was expanded by designing the MARK-U3 system for integration with a mobile water-quality robot. Figs. 5 and 6 show the conceptual layout and a 3D model of the mobile robot-integrated MARK-U3 platform. The robot featured a 3×3×1.4 m floating frame equipped with propulsion motors, solar power units, LiDAR, IMU sensors, and a dedicated control module. MARK-U3 functioned as a modular payload, enabling automated sampling at multiple locations without redeployment. The integration of the MARK-U3 system with the mobile water-quality robot significantly expanded the spatial capabilities of marine radiological monitoring. In contrast to previous buoy systems (e.g., Song et al. 2023) that focused on stationary monitoring, the optimized MARK-U3 is expected to show a comparable or superior MDA (0.87 Bq·L−1 based on these simulation results) while uniquely providing automated cleaning and mobile-robot-based spatial coverage. During field deployment, the robot successfully transported the MARK-U3 unit between multiple sampling stations separated by several hundred meters. At each location, the system performed sampling and analysis autonomously without requiring manual setup or recalibration. The combined platform maintained structural and operational stability while in transit. The reinforced flotation structure of the buoy effectively dampened lateral motion during movement, and sampling geometry remained consistent even after the robot changed heading or speed. This stability ensured that the sampling inlet returned to its correct operating configuration at each designated stop.
The measurements taken from different stations revealed noticeable spatial variability in environmental parameters and radiological signals. Such variability underscores the value of a mobile monitoring platform because fixed-point buoys may fail to capture dynamic or localized changes in marine radiological conditions. The field results showed that mobile deployment enables rapid identification of environmental anomalies and allows for adaptive sampling strategies during emergency-response operations. Overall, the integrated MARK-U3–robot system showed the ability to sustain continuous operation during extended field trials, collecting reliable radiological data at multiple locations, and highlighting its potential as a flexible tool for comprehensive marine environmental assessments.

4. Conclusions

This paper presented an optimized design of the MARK-U3 floating marine radiological monitoring system, addressing key limitations identified in earlier field deployments. The revised configuration is anticipated to improve the detection sensitivity, sampling accuracy, and overall stability during offshore operation through systematic enhancements to the sampling mechanism, structural buoyancy, automated cleaning, and depth-control functions. The adoption of a hybrid solar–battery power module and LTE-based communication further confirmed the capability of the system for reliable long-term autonomous monitoring. In addition, integration with a mobile water-quality robot expanded the monitoring range beyond fixed-point operation, enabling spatially distributed sampling and supporting more flexible responses to potential marine radiological events. These improvements suggest that the optimized MARK-U3 system is suitable for routine environmental surveillance and is adaptable for rapid deployment in emergencies requiring timely radiological assessment. Future work will focus on expanding multi-sensor integration and evaluating the long-term stability across diverse marine environments, further strengthening the potential of the system as a core component of advanced marine radiological monitoring networks.

Conflict of Interest

No potential conflict of interest relevant to this article was reported.

Funding

This research was supported by the National Research Foundation of Korea (NRF), funded by the Ministry of Science and ICT (RS-2022-00144210).

Fig. 1
Initial deployments of the MARK-U3 floating marine monitoring system
ksoe-2025-075f1.jpg
Fig. 2
Prototype design of the MARK-U3 system incorporating buoyancy-reinforcement components
ksoe-2025-075f2.jpg
Fig. 3
Overview of the optimized MARK-U3 system showing its external structure, internal components, and sampling-pump configuration
ksoe-2025-075f3.jpg
Fig. 4
Efficiency and volume parameter depending on the sample volume
ksoe-2025-075f4.jpg
Fig. 5
Conceptual design of mobile robot-based MARK-U3 monitoring system
ksoe-2025-075f5.jpg
Fig. 6
3D conceptual model of mobile robot-based MARK-U3 floating marine radiological monitoring system
ksoe-2025-075f6.jpg
Table 1
Technical requirement analysis for improving the floating seawater sampling and in situ measurement system (MARK-U3)
Category Key requirements Remarks
Sampling container volume Expanding the sampling container to 3 L is necessary to achieve a lower MDA during on-site radiological measurements. Increased shielding volume may lead to a heavier system, but the buoyancy of a floating structure can offset the added mass. Additional shielding performance analysis is required.
Pump selection Peristaltic pumps provide quantitative accuracy but are limited by low flow rates. Diaphragm pumps allow high-flow sampling but require supplementary mechanisms to ensure volumetric accuracy. The baseline configuration uses a diaphragm pump with a visual overflow-based 3 L verification. Redundancy in pumps and valves is recommended to mitigate the risks of malfunction.
Depth-resolved sampling method Stable underwater sampling can be achieved using weighted piping combined with a cable-winch system to maintain a fixed depth. A CTD sensor may be integrated to record depth, salinity, and temperature, supporting environmental interpretation. Sensor accuracy considerations are required.
Sampling container cleaning system When radioactivity is detected, the sampling container must be flushed with uncontaminated water before the next sampling cycle to prevent cross-contamination. A dedicated 20–30 L cleaning water reservoir is recommended in the lower buoy section. When cleaning water is depleted, the system must switch to an alternative operation mode. The type of cleaning water and flushing efficiency requires evaluation.
Power supply and control system A low-power architecture combined with solar panels and a high-capacity battery enables at least 3 days of autonomous operation. LTE-based communication enables remote control and data transmission. A modular design improves maintainability. Waterproofing and anti-corrosion measures are needed for long-term deployment.
Table 2
Comparison of performance specifications between the baseline and optimized MARK-U3 systems
Category Baseline MARK-U3 Optimized MARK-U3 Quantitative Improvement
Sampling volume 2 L (Variable due to tilting) 3 L (Fixed) 50% volume increase
Pump mechanism Peristaltic pump Diaphragm pump Stable flow rate
Structural stability Unstable (Significant tilting) Vertical alignment Constant measurement geometry
Sensitivity (MDA) 1.13 Bq·L−1 (at 3,600 s) ~ 0.87 Bq·L−1 (Factor of 30% reduction) Enhanced sensitivity (Theoretical)

References

Joung, S., Ji, Y., & Choi, Y. (2023). Development of a floating radiation measurement system for underwater readings in the East Sea of Korea. Journal of Coastal Research, 39(2), 384-393. https://doi.org/10.2112/JCOASTRES-D-22TM-00014.1
crossref
Song, J., Gong, P., Wang, P., Zhang, J., Hu, Z., Zhou, C., Zhu, X., Wei, Q., Zhou, J., & Tang, X. (2023). Unmanned stationary online monitoring system based on buoy for marine gamma radioactivity. Applied Radiation and Isotopes, 191, 110528. https://doi.org/10.1016/j.apradiso.2022.110528
crossref pmid
Tsabaris, C., Androulakaki, E. G., Alexakis, S., & Patiris, D. L. (2018). An in-situ gamma-ray spectrometer for the deep ocean. Applied Radiation and Isotopes, 142, 120-127. https://doi.org/10.1016/j.apradiso.2018.08.024
crossref pmid
Zhang, Y., Bi, H., Wu, B., Yuan, D., Shi, Y., & Feng, X. (2022). Gamma spectrum analysis for in situ automatic monitoring of radioactivity in seawater. Journal of Radioanalytical and Nuclear Chemistry, 331, 3723-3733. https://doi.org/10.1007/s10967-022-08433-8
crossref
TOOLS
Share :
Facebook Twitter Linked In Google+ Line it
METRICS Graph View
  • 0 Crossref
  •   Scopus
  • 2,787 View
  • 45 Download


ABOUT
BROWSE ARTICLES
ARTICLE CATEGORY

Browse all articles >

PUBLICATION ETHICS
FOR CONTRIBUTORS
Editorial Office
President Office BD Rm. 1302, 13 Jungang-daero 180beon-gil, Dong-gu, Busan 48821, Republic of Korea
Tel: +82-51-759-0656    Fax: +82-51-759-0656    E-mail: ksoehj@ksoe.or.kr                

Copyright © 2026 by The Korean Society of Ocean Engineers.

Developed in M2PI

Close layer
prev next