Park, Lee, Son, Jeon, Choi, and Yang: Numerical Study on Air-Intake Louver for Polar Ships

Abstract

Because of global warming, the sea ice in the Arctic is rapidly decreasing, thus resulting in the formation of new shipping routes. In this study, we investigate the design of an anti-icing structure for air-intake louvers on ships operating in polar waters, with emphasis on energy efficiency. The louver, which is composed of multiple blades mounted on a ship’s outer plating, is heated with a heat-transfer fluid to prevent ice formation. Numerical techniques were employed to design the louvers for efficient energy use and consistent heating. To assess the risk of icing, a steady-state thermal analysis was performed with a safety margin, with emphasis on the blade with the lowest heat-transfer fluid temperature. The piping size for the fluid in each blade was optimized to ensure uniform heat distribution. The results indicate that icing is unlikely to occur in the moisture-separation section of the louver due to heat transferred from the heat-transfer fluid. In conclusion, polar ships equipped with the optimally designed air-intake louvers is expected to prevent energy losses caused by excessive supply and ensure safe navigation without the occurrence of icing.

Nomenclature

ν : Kinematic viscosity coefficient (cSt, 10−6 m2/s)
ρ : Density (g/cm3)
C : Heat capacity (kJ/kg·K)
k : Thermal conductivity (W/(m·K))
Γk : Diffusion coefficient (m2/s)
e : Specific energy (J)
r : Specific heat (J)
Vi : Inlet velocity (m/s)
ΔP : Pressure loss (Pa)

1. Introduction

By the 2030s, the Arctic region is expected to transform into an environment where all ice melts in the summer and freezes again in the winter because of global warming. The ice in the Arctic region will evolve from permanent ice to seasonal ice, thus facilitating ship navigation along Arctic routes. The lowest temperature observed in the Arctic was −67.8 °C in Siberia in 1892 (Korea Hydrographic and Oceanographic Agency, n.d.). Even in the warmest months, the average temperature in the Arctic is lower than 10 °C owing to the effect of cold Arctic air masses (Ministry of Foreign Affairs Republic of Korea, n.d.). However, the recent global warming has caused a rapid decrease in the Artic sea ice, thus resulting in the formation of new shipping routes.
The use of Arctic shipping routes reduces the distance from Asia to Europe by approximately 30% compared with the existing maritime transport routes via the Suez Canal. Moreover, the sailing time is expected to be reduced by approximately 10 days. Additionally, a reduction in logistics costs is anticipated. Therefore, Arctic shipping routes have garnered global attention. Domestic and overseas shipping companies are considering the utilization of Arctic shipping routes as the shortest international transport routes between Europe and Asia, and the Russian government is planning international transport routes to transport hydrocarbon resources (e.g., LNG, petroleum, and coal) produced in the Arctic region to European and Asian markets (Institute of Arctic Logistics, 2004).
The construction volume of ships to sail Arctic shipping routes is increasing, and related technologies, equipment, and materials (e.g., icing prevention, de-icing, thermal insulation, and low-temperature steel) are being developed and applied to polar ships. Additionally, the International Maritime Organization has mandated the application of the polar code from January 1, 2017 to ensure the safety of newly constructed polar ships (International Maritime Organization, 2017).
Min et al. (2011) analyzed the elastic–plastic material properties of classification steel for icebreaking vessels as basic data to investigate the structural behavior characteristics of icebreaking vessels. Jeong et al. (2011) derived anti-icing construction standards for weathertight doors by performing low-temperature performance evaluation based on the anti-icing construction method. Lee (2022) analyzed an anti-icing system that applies heating blades equipped with a carbon nanotube-based anti-icing function to air-vent louvers installed in ships and marine structures operating in polar waters. Additionally, domestic equipment and material manufacturers have developed products such as deck passages and railings (Jeong et al., 2019). Polar ships, equipment, and materials have been investigated extensively (Yi and Chin, 2018; Lee, 2019; Kim et al., 2017).
In this study, the anti-icing structure of air-intake louvers for ships operating in polar waters was designed from an energy perspective. Louvers installed on the ship’s outer plating comprise multiple blades, and heat is supplied to each blade to prevent icing. They must be designed such that icing cannot occur even in the least heated blade. Therefore, uniformly supplied heat can prevent the waste of thermal energy caused by excessive supply. Numerical techniques were used to enable a uniform heat supply to each blade.

2. Numerical Analysis of Air-intake Louvers

2.1 Air-intake Louver

Ships must draw in external air and discharge indoor air to the outside for indoor temperature control and ventilation. In particular, in the engine compartment where various machines, including the engine, are installed, a significant amount of air must be circulated for engine and equipment operation. Thus, an air-conditioning system composed of air-intake louvers, fans, and ducts is installed. An air-intake louver comprises multiple blades, as shown in Fig. 1. It is installed on the ship’s outer plating to draw in external air. Water separators that remove water from the air are applied to louver blades to inhibit the entrance of water, including on snowy or rainy days, as shown in Fig. 2.
However, for air-intake louvers of ships that operate in polar waters, separated water can freeze at the moisture-separation section, which may affect the safety of the ship and its crew by obstructing the air inlet. Therefore, an anti-icing structure that uses electric heat tracing or a thermal-transfer fluid should be applied to air-intake louvers to prevent icing.
Electric heat tracing, which converts electrical energy into thermal energy, is commonly used in ships operating in low-temperature environments. In electric heat tracing, the associated equipment can be easily installed and maintained, and precise temperature control is enabled through sensors. However, its application is limited due to restrictions on heat capacity. Therefore, polar ships generally use thermal-transfer fluids to respond to icing. In this study, Polyester’s Termolan H, which is applicable at both high and low temperatures and safe for human health, was used as a thermal-transfer fluid. The physicochemical and thermophysical properties of Termolan H are listed in Tables 1 and 2, respectively.
To effectively separate water and prevent the freezing of separated water, the air-intake louver blade was designed by implementing moisture-separation sections and thermal-transfer fluid piping, as shown in Fig. 3. Two moisture-separation sections were applied to each blade, around which thermal-transfer fluid piping was installed.
The air-intake louver featured a width of 1 m and a height of 1 m, and 17 blades were applied to it, as shown in Fig. 4. Thermal-transfer fluid was introduced through the upper piping. It flowed into each blade and was discharged through the lower piping. Except for the structure for fixation on the hull, the entire piping of the thermal-transfer fluid and the blades were modeled using Ansys Inc.’s DesignModeler (Ver. 2022), as shown in Fig. 5.

2.2 Methodology

Heating was performed through the thermal-transfer fluid to prevent icing in the blades of the air-intake louver. Moreover, a design that supplies uniform heat to all blades was required to prevent losses due to excessive energy supply and avoid icing even in the least heated blade. In this study, three-dimensional (3D) numerical analysis was conducted to evaluate the temperature distribution and uniformity of the thermal-transfer fluid.
The geometric model used for the analysis was constructed using Ansys DesignModeler (Ver. 2022), and the grid for the inside of the thermal-transfer fluid piping was generated through the Ansys Meshing module. The grid system was constructed based on unstructured irregular hexahedrons, and Ansys Fluent (Ver. 2022)―a commercial software program based on the finite-volume method―was used for flow and heat-transfer analysis. Numerical analysis was conducted based on the semi-implicit method for pressure linked equations algorithm, which is a pressure–velocity coupling technique.
The analysis target was assumed to be a single-phase incompressible flow, and governing equations based on mass, momentum, and energy conservation laws were applied for the overall analysis. Among them, the transport equation for the generalized scalar variable ∅j is expressed as follows (Ansys, 2009):
(1)
∂ρ∅j∂t+∂∂xi(ρui∅i-Γk∂∅j∂xi)=S∅j
where ρ is the density, ui the i-direction velocity component, xi the spatial coordinate, Γk the diffusion coefficient, S ∅j the source term, and ∅j the general scalar physical quantity (e.g., energy and temperature). Additionally, j is an index variable that indicates one of several scalar physical quantities (e.g., energy, concentration, and turbulence variables).
Under incompressible flow, energy conservation is expressed as follows:
(2)
∂ρe∂t+∇·(ρu→e)=∇·(k Δ T)+ρr
where e is the internal energy per unit mass, k the thermal conductivity, T the temperature, and r the heat quantity per unit mass.
In this study, the flow and temperature distribution of the thermal-transfer fluid were analyzed under steady-state conditions. Thus, the time derivative terms in Eqs. (1) and (2) were omitted from analysis.
To select a grid model for numerical analysis, four models with different maximum element sizes were verified. The maximum element size and the number of elements for each model are listed in Table 3. Fig. 6 shows the computational domain and boundary conditions. The thermal-transfer fluid was supplied to the louver through piping with an inner diameter of 16.4 mm and then separated into each blade of the louver to transfer heat. In each blade, piping with an inner diameter of 10.5 mm was installed in two moisture-separation sections. Subsequently, the thermal-transfer fluid was discharged to the outside through piping with an inner diameter of 16.4 mm. Velocity inlet and pressure outlet boundary conditions were applied to the inlet and outlet, respectively, while no-slip boundary conditions were applied to the wall. Termolan H, which is the thermal-transfer fluid, was supplied through the inlet of the louver at a temperature of 20 °C. Additionally, a heat-transfer coefficient of 26 W/m2K was applied to the wall considering an external air temperature of −52 °C and a wind speed of 2.7 m/s, which are the design conditions of polar ships, as shown in Fig. 7 (Osczevski, 1995). For grid verification, the average temperatures at the center of each blade (as shown in Fig. 6) were compared under an inlet flow velocity Vi of 0.9 m/s. The analysis results are shown in Fig. 8. The G2 model and the maximum element size were selected to ensure accuracy and efficiency, as shown in Fig. 9.
In this study, the uniformity of the heat supplied into each blade by the thermal-transfer fluid was numerically evaluated, and the average temperatures of the thermal-transfer fluid separated into each blade, which were measured 400 mm below the center of the louver (as shown in Fig. 6) were compared. The difference between the maximum temperature (TMAX ) and minimum temperature (Tmin) of the thermal-transfer fluid separated into each blade at the corresponding position is denoted as ΔTb.
(3)
Δ Tb=TMAX-Tmin

2.3 Numerical Analysis

Numerical analysis was conducted for the case involving the same inner piping diameter (10.5 mm) for the thermal-transfer fluid separated into each blade. The analysis results for Vi = 0.5, 0.6, 0.7, 0.8, 0.9, and 1.0 m/s are shown in Table 4 and Fig. 10. The total pressure loss of the thermal-transfer fluid, ΔP, is included as well.
Although ΔTb was 49.2 K when the inlet flow velocity was 0.5 m/s, the ΔTb of each blade decreased gradually and the uneven heat supply resolved gradually as the flow velocity increased. However, ΔP increased significantly with the flow velocity. Fig. 11 shows the temperature distribution of the thermal-transfer fluid under Vi = 0.6 m/s. The thermal-transfer fluid supplied through the upper piping was distributed into the piping of each blade. Relatively high temperatures were maintained at the measurement points of each blade close to the inlet owing to the efficient supply of the thermal-transfer fluid. However, as the distance from the inlet increased, the temperature decreased gradually owing to the reduced flow rate of the supplied fluid caused by pressure loss.
To ensure a homogeneous supply of heat to each blade even under moderate/low flow velocities, the size of the piping installed in the No. 17 blade, which exhibited the lowest temperature, was adjusted. Considering the production of the air-intake louver, nominal pipe sizes were applied in this study. Specifically, sizes of 11.8, 12.5, 13.4, and 13.8 mm were considered in addition to the original size of 10.5 mm as the piping diameter of the No. 17 blade. The analysis results for Vi = 0.5, 0.6, and 0.7 m/s are shown in Tables 5,–7 and Figs. 12,–14, respectively. At Vi = 0.5 m/s, ΔTb was 49.2K for the original louver with a pipe diameter of 10.5 mm. As the piping size of the No. 17 blade increased, however, ΔTb decreased gradually and reached 2.6 K at an inner diameter of 13.4 mm. At a pipe diameter of 13.8 mm, however, ΔTb increased compared with that at a pipe diameter of 13.4 mm owing to a significant increase in the flow rate of the thermal-transfer fluid supplied to the No. 17 blade. Additionally, ΔP decreased gradually as the pipe diameter of the No. 17 blade increased due to the improved flow of the thermal-transfer fluid. At Vi = 0.6 and 0.7 m/s, ΔTb decreased gradually as the piping size of the No. 17 blade increased, thus resulting in the least difference at an inner diameter of 13.4 mm. At a pipe diameter of 13.8 mm, ΔTb was greater than that at an inner diameter of 13.4 mm. Additionally, as in the case of Vi = 0.5 m/s, ΔP decreased slightly as the pipe diameter of the No. 17 blade increased. Fig. 15 shows the temperature distribution of the thermal-transfer fluid under a pipe diameter of 13.44 mm for the No. 17 blade and Vi = 0.6 m/s.
The pipe diameter of the No. 17 blade was determined to be 13.4 mm. To supply heat more evenly, the thermal-transfer fluid temperatures of each blade were compared within the inlet flow velocity range of 0.5–0.7 m/s, as shown in Fig. 16. The pipe diameters of the No. 2, 3, and 16 blades, which exhibited relatively low temperatures, were adjusted considering nominal pipe sizes.
The pipe diameters of the No. 2, 3, and 16 blades were changed from the original size of 10.5 mm to 10.8 and 11.8 mm. The analysis results for Vi = 0.5, 0.6, and 0.7 m/s are shown in Tables 8,–10 and Figs. 17,–19, respectively. At Vi = 0.5 m/s, ΔTb was 2.6 K for the original louver with a pipe diameter of 10.5 mm; however, it decreased to 2.0 K as the pipe diameter of the No. 2, 3, and 16 blades increased to 10.8 mm. At a pipe diameter of 11.8 mm, however, ΔTb increased to 4.3 K owing to the significant increase in the flow rates of the blades. Meanwhile, ΔP decreased as the pipe diameter increased owing to the improved flow of the thermal-transfer fluid inside the louver. At Vi = 0.6 and 0.7 m/s, the least temperature difference was also observed when the pipe diameter of the No. 2, 3, and 16 blades was 10.8 mm, whereas the temperature difference increased at a pipe diameter of 11.8 mm. In the case of the air intake louver with a pipe diameter of 13.4 mm for the No. 17 blade and 10.8 mm for the No. 2, 3, and 16 blades, the temperature distribution of the thermal-transfer fluid at Vi = 0.6 m/s is shown in Fig. 20.
To ensure an even supply of heat to each blade of the air-intake louver, the pipe diameter of the No. 17 blade was set to 13.4 mm and that of the No. 2, 3, and 16 blades to 10.8 mm. Table 11 shows the temperature of the thermal-transfer fluid at each temperature-measurement point under Vi = 0.6 m/s. The fluid temperature was the lowest (10.0 °C) in the No. 3 blade.
Numerical analysis was conducted to evaluate whether icing occurred in the No. 3 blade, which exhibited the lowest temperature (10.0 °C) for the thermal-transfer fluid. The condensation temperature of moisture is 0 °C; however; a moisture-separation section temperature of at least 5 °C was targeted in this study, considering a safety margin of 5 °C. Two-dimensional (2D) modeling of the blade cross-section was generated using Ansys Inc.’s Mechanical (Ver. 2022), as shown in Fig. 21. The number of grid elements was 5,200. A heat-transfer coefficient of 26 W/(m2·K) was applied to the external wall of the blade considering a wind speed of 2.7 m/s, and −52 °C was applied as the external air temperature. A temperature boundary condition of 10.0 °C was applied to the walls of the two pipes inside the blade for analysis.
Fig. 22 shows the steady-state thermal analysis results for the blade cross-section. The temperature of the moisture-separation sections exceeded 5.4 °C owing to heat transferred from the thermal-transfer fluid. This indicates that the separated moisture will not condense.

3. Conclusions

Global warming has facilitated ship navigation along Arctic routes. As this is expected to decrease the sailing time and logistics costs compared with the case of existing transport routes, Arctic routes have garnered global attention. Additionally, Artic routes have been developed as international transport routes for hydrocarbon resources, such as LNG, owing to the increased development of resources in the Arctic region.
In this study, an air-intake louver-installed on ships operating in polar waters was designed from an energy perspective. The louver composed of multiple blades was heated by a thermal-transfer fluid to prevent icing. To ensure an even supply of heat to each blade, the size of the thermal-transfer fluid piping passing through each blade was adjusted using nominal pipe sizes. Under Vi = 0.6 m/s and a pipe diameter of 10.4 mm for all blades, the difference between the TMAX and TMIN of the fluid at the bottom of each blade was 44.0 K. The piping size of the blades that exhibited the lowest temperature, however, was adjusted twice. The difference between the TMAX and TMIN of the fluid under the same Vi was reducible to 1.4 K.
To evaluate whether icing occurs in the finally designed air-intake louver, steady-state thermal analysis was conducted on the blade with the lowest thermal-transfer fluid temperature while considering a safety margin. The thermal-analysis results for the blade cross-section showed that the temperature of the moisture-separation sections exceeded 5.4 °C owing to heat transferred from the thermal-transfer fluid, thus indicating that icing will not occur in the louver.
In this study, the air-intake louver was designed using nominal pipe sizes to facilitate production. However, the production cost may be further reduced if the piping of each blade is designed in the same size. Installing pipes of the same size and adjusting the flow rate of the thermal-transfer fluid by installing an orifice in some pipes as opposed to the approach adopted by this study, may be an alternative.
In the future, the numerical analysis results shall be verified through experiments performed in a low-temperature cold-room facility after fabricating the air-intake louver designed in this study.

Conflict of Interest

No potential conflict of interest relevant to this study was reported.

Fig. 1
Air-intake louver for general ships
ksoe-2025-004f1.jpg
Fig. 2
Louver blade and water separator for general ships
ksoe-2025-004f2.jpg
Fig. 3
Louver blade design for present study (units: mm)
ksoe-2025-004f3.jpg
Fig. 4
Air-intake louver for present study (units: mm)
ksoe-2025-004f4.jpg
Fig. 5
3D modeling of air-intake louver
ksoe-2025-004f5.jpg
Fig. 6
Solution domain (units: mm)
ksoe-2025-004f6.jpg
Fig. 7
Heat-transfer coefficient for polar ships (Osczevski, 1995)
ksoe-2025-004f7.jpg
Fig. 8
Results of grid-refinement tests
ksoe-2025-004f8.jpg
Fig. 9
3D modeling of heat-transfer fluid of air-intake louver
ksoe-2025-004f9.jpg
Fig. 10
Temperature results of original louver for various inlet velocities (m/s)
ksoe-2025-004f10.jpg
Fig. 11
Temperature contour of original louver (Vi = 0.6 m/s)
ksoe-2025-004f11.jpg
Fig. 12
Temperature results of first modified louvers for various diameters of pipe No. 17 (Vi = 0.5 m/s)
ksoe-2025-004f12.jpg
Fig. 13
Temperature results of first modified louvers for various diameters of pipe No. 17 (Vi = 0.6 m/s)
ksoe-2025-004f13.jpg
Fig. 14
Temperature results of first modified louvers for various diameters of pipe No. 17 (Vi = 0.7 m/s)
ksoe-2025-004f14.jpg
Fig. 15
Temperature contour of first modified louver (Vi = 0.6 m/s)
ksoe-2025-004f15.jpg
Fig. 16
Temperature result of first modified louver for various inlet velocities (m/s, Db17 = 13.4 mm)
ksoe-2025-004f16.jpg
Fig. 17
Temperature results of second modified louvers for various diameters of pipe nos. 2, 3, and 16 (Vi = 0.5 m/s)
ksoe-2025-004f17.jpg
Fig. 18
Temperature results of second modified louvers for various diameters of pipe nos. 2, 3, and 16 (Vi = 0.6 m/s)
ksoe-2025-004f18.jpg
Fig. 19
Temperature results of second modified louvers for various diameters of pipe nos. 2, 3, 16 (Vi = 0.7 m/s)
ksoe-2025-004f19.jpg
Fig. 20
Temperature contour of second modified louver (Vi = 0.6 m/s)
ksoe-2025-004f20.jpg
Fig. 21
2D modeling of air-intake louver blade
ksoe-2025-004f21.jpg
Fig. 22
Thermal-analysis result of air-intake louver blade
ksoe-2025-004f22.jpg
Table 1
Physicochemical parameters of Termolan H
Indicator name Value
Density at 20 °C 0.850–0.890 g/cm3
Flash point in open cup not less than 190 °C
Pour point less than −30 °C
Boiling point not less than 330 °C
Table 2
Thermophysical parameters of Termolan H
T (°C) ν (cSt, 10 −6 m2/s) ρ (g/cm3) C (kJ/kg·K) k (W/(m·K))
−20 1150 0.878 1.63 0.100
0 159 0.865 1.70 0.099
20 58.2 0.853 1.78 0.097
40 21.4 0.842 1.86 0.095
60 10.1 0.832 1.94 0.093
80 6.5 0.820 2.05 0.091
100 4.2 0.810 2.13 0.090
Table 3
Cases for grid-refinement tests
Case G1 G2 G3 G4
Maximum element size 0.005 0.0025 0.002 0.0015
Elements 4,954k 6,716k 8,296k 13,283k
Table 4
Analysis results of the original louver
Vi (m/s) 0.5 0.6 0.7 0.8 0.9 1.0
ΔTb (K) 49.2 44.0 11.6 7.4 5.9 4.5
ΔP (kPa) 1.85 2.12 2.42 2.78 3.18 3.57
Table 5
Analysis results of first modified louvers (Vi= 0.5 m/s)
No. 17 blade Diameter (mm) 10.5 (original) 11.8 12.5 13.4 13.8
ΔTb (K) 49.2 36.3 4.8 2.6 3.3
ΔP (kPa) 1.85 1.80 1.68 1.65 1.63
Table 6
Analysis results of first modified louvers (Vi = 0.6 m/s)
No. 17 blade Diameter (mm) 10.5 (original) 11.8 12.5 13.4 13.8
ΔTb (K) 44.0 6.2 3.3 2.5 2.7
ΔP (kPa) 2.12 2.03 2.00 1.98 1.95
Table 7
Analysis results of first modified louvers (Vi = 0.7 m/s)
No. 17 blade Diameter (mm) 10.5 (original) 11.8 12.5 13.4 13.8
ΔTb (K) 11.6 4.2 2.5 2.3 2.5
ΔP (kPa) 2.42 2.37 2.34 2.32 2.29
Table 8
Analysis results of second modified louvers (Vi = 0.5 m/s)
No. 2, 3, and 16 blades Diameter (mm) 10.4 (original) 10.8 11.8
ΔTb (K) 2.6 2.0 4.3
ΔP (kPa) 1.65 1.63 1.58
Table 9
Analysis results of second modified louvers (Vi = 0.6 m/s)
No. 2, 3, and 16 blades Diameter (mm) 10.4 (original) 10.8 11.8
ΔTb (K) 2.6 1.4 2.8
ΔP (kPa) 1.98 1.95 1.89
Table 10
Analysis results of second modified louvers (Vi = 0.7 m/s)
No. 2, 3, and 16 blades Diameter (mm) 10.4 (original) 10.8 11.8
ΔTb (K) 2.3 1.6 2.8
ΔP (kPa) 2.32 2.29 2.22
Table 11
Fluid temperature result of second modified louver (Vi = 0.6 m/s)
Blade No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
T (°C) 10.1 10.4 10.0 10.6 10.5 11.1 11.0 11.3 11.4 11.2 11.2 11.2 10.9 10.8 10.6 10.7 10.3

References

Ansys. (2009). Ansys Fluent 12.0 Theory Guide, Ansys, Inc.

International Maritime Organization (IMO). (2017). International Code for Ships Operating in Polar Waters (Polar Code).

Institute of Arctic Logistics. (2024) February 14. 최근의 북극항로 환경 변화 및 시사점. Recent environmental changes in the Arctic maritime shipping route and implications Arctic Shipping Newsletter. 100: http://arctic.ysu.ac.kr/ial/bbs/board.php?bo_table=newsletter&wr_id=114

Jeong, S. Y., Chun, E. J., Cho, S. R., & Lee, C. J. (2011). A study on anti-icing technique for weather-tight door of ice-strengthened vessels. Journal of the Society of Naval Architects of Korea, 48(6), 575-580. https://doi.org/10.3744/SNAK.2011.48.6.575
crossref
Jeong, S. Y., Kang, K. J., & Jang, J. H. (2019). A review of winterization trend for vessels operating in ice-covered waters. Journal of the Society of Naval Architects of Korea, 56(2), 135-142. https://doi.org/10.3744/SNAK.2019.56.2.135
crossref
Kim, S. H., Luo, Y., Shi, C., & Lee, C. H. (2017). A study on the effect of ice impact forces on an ice-strengthened polar class ship after a collision with an iceberg. Journal of the Korean Society of Marine Environment & Safety, 23(1), 40-46. https://doi.org/10.7837/kosomes.2017.23.1.040
crossref
Korea Hydrographic and Oceanographic Agency. (n.d). 북극항해안전 소개. Introduction to Polar Navigation Safety https://www.khoa.go.kr/polar/intr.antarcticClimate.do

Lee, J. G. (2022). A study on the design method of air vent louver for ice prevention in polar marine field by numerical simulation. Journal of Korean Society Mechanical Technology, 24(3), 504-513. http://doi.org/10.17958/ksmt.24.3.202206.504
crossref
Lee, S. C. (2019). Development of environmental load analysis simulator for polar ships and offshore plants. Bulletin of the Society of Naval Architects of Korea, 56(2), 33-37.

Min, D. K., Shim, C. S., Shin, D. W., & Cho, S. R. (2011). On the mechanical properties at low temperature for steels of ice-class vessels. Journal of the Society of Naval Architects of Korea, 48(2), 171-177. https://doi.org/10.3744/SNAK.2011.48.2.171
crossref
Ministry of Foreign Affairs Republic of Korea. (n.d). 북극소개. Introduction to the Arctic – Arctic Overview https://www.mofa.go.kr/www/wpge/m_4045/contents.do

Osczevski, R. J. (1995). The basis of wind chill. Arctic. 48(4), 372-382. https://www.jstor.org/stable/40511941
crossref
Yi, C. S., & Chin, D. H. (2018). A study on the flow analysis of ventilation louver for polar ship. Journal of the Korean Society of Manufacturing Process Engineers, 17(5), 16-22. http://doi.org/10.14775/ksmpe.2018.17.5.016
crossref


ABOUT
BROWSE ARTICLES
ARTICLE CATEGORY

Browse all articles >

PUBLICATION ETHICS
FOR CONTRIBUTORS
Editorial Office
President Office BD Rm. 1302, 13 Jungang-daero 180beon-gil, Dong-gu, Busan 48821, Republic of Korea
Tel: +82-51-759-0656    Fax: +82-51-759-0656    E-mail: ksoehj@ksoe.or.kr                

Copyright © 2026 by The Korean Society of Ocean Engineers.

Developed in M2PI

Close layer
prev next