The Estimation of Defect of Mono Cast Nylon by Infrared Thermography
Han Jeong-Seb
Dept. of Materials Science and Engineering DonA Univ.
열화상 기술에 의한 M.C 나일론의 내부 결함에 대한 평가
한정섭
동아대학교 신소재공학과
© 2009 The Korean Society of Ocean Engineers     Open access / Under a Creative Commons License
Keywords: Infrared thermography, Defect depth, Non-destructive testing, The full width at half of the maximum contrast, Mono cast nylon
핵심용어: 적외선 열화상, 결함의 깊이, 비파괴시험, 반치폭, 엠씨 나일론
Abstract
Infrared thermography was used to determine the location, size, and depth of defects under the surface of M.C nylon. Defects were created in a specimen by back-drilling circular holes. These defects were located at the maximum temperature difference that occurred. The sizes of the defects could be calculated by means of the full width at half of the maximum temperature difference. The depth of a defect could be calculated by the peak time and the maximum temperature difference. The maximum temperature difference between a defect and normal part was decreased with the depth of the defect. And the peak time also slowly appeared with the depth of the defect.
TOOLS
Share :
Facebook Twitter Linked In Google+ Line it
METRICS Graph View
  • 747 View
  • 1 Download
Related article in JOET

Determination of Density Noise in a Two-Phase-Flow by X-ray Computer Tomography1989 June;3(1)



ABOUT
BROWSE ARTICLES
ARTICLE CATEGORY

Browse all articles >

PUBLICATION ETHICS
FOR CONTRIBUTORS
Editorial Office
President Office BD Rm. 1302, 13 Jungang-daero 180beon-gil, Dong-gu, Busan 48821, Republic of Korea
Tel: +82-51-759-0656    Fax: +82-51-759-0656    E-mail: ksoehj@ksoe.or.kr                

Copyright © 2023 by The Korean Society of Ocean Engineers.

Developed in M2PI

Close layer
prev next